BQYXJ - BRAYCO MICRONIC 790-150AW
- MSDS: BQYXJ
- Manufacturer: CASTROL INC SPECIALTY PRODUCTS DIV
- Product Name: BRAYCO MICRONIC 790-150AW
- National Stock Number: 9150-00F027007
Product Identification
Product ID:BRAYCO MICRONIC 790-150AW
MSDS Date:10/31/1988
FSC:9150
NIIN:00F027007
MSDS Number: BQYXJ
Responsible Party
IRVINE, CA 92714
US
Emergency Phone: 714-660-9414
Info Phone: 714-660-9414
Preparer: KAREL WRIGHT
Cage: EO453
Contractor
Telephone: 630-241-4140
Cage: 2R128
Ingredients
PETROLEUM HYDROCARBONS
ORGANIC ZINC COMPOUND
Fraction By Weight: 1.5%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION & REDNESS. SKIN:
REDNESS, DEFATTING, DERMATITIS, & IRRITATION. INHALATION: NASAL &
RESPIRATORY TRACT IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: DEFATTING & DISORDERS.
First Aid
First Aid:EYES: FLUSH W/LARGE AMOUNTS OF CLEAN WATER FOR AT LEAST 15
MINS. SKIN: WASH THOROUGHLY W/SOAP & WATER. INHALATION: REMOVE TO
FRESH AIR. ADMINISTER OXYGEN IF NECESSARY. INGESTION: DON'T INDUCE
VOMITING . ASPIRATION HAZARD. OBTAIN MEDICAL ATTENTION IN ALL
CASES.
Fire Fighting
Flash Point Method:COC
Flash Point:450F
Extinguishing Media:DRY CHEMICAL, CO2, FOAM
Fire Fighting Procedures:USE WATER AS FOG/SPRAY TO COOL FIRE EXPOSED
CONTAINERS. USE SELF-CONTAINED BREATHING APPARATUS IN CONFINED
AREAS.
Unusual Fire/Explosion Hazard:EMPTY CONTAINERS MAY RETAIN PRODUCT
RESIDUE OR VAPORS WHICH CAN IGNITE EXPLOSIVELY.
Accidental Release
Spill Release Procedures:DON'T PERMIT PRODUCT TO ENTER
STREAMS/SEWERS/OTHER WATERWAYS. REMOVE SOURCES OF IGNITION. DIKE
SPILL & ELIMINATE LEAK. ABSORB W/INERT MATERIAL & STORE IN CLOSED
CONTAINERS UNTIL DISPOSAL.
Handling
Handling and Storage Precautions:MAINTAIN AMBIENT TEMPERATURES. KEEP
CONTAINER TIGHTLY CLOSED. MAINTAIN ADEQUATE VENTILATION. DON'T
CUT/DRILL/WELD ON OR NEAR FULL OR EMPTY CONTAINERS.
Other Precautions:AVOID PROLONGED/REPEATED BREATHING OF
VAPORS/MISTS/FUMES. DON'T STORE NEAR HEAT/FLAMES/STRONG OXIDANTS.
Exposure Controls
Respiratory Protection:CHEMICAL CARTRIDGE RESPIRATOR OR SUPPLIED AIR
RESPIRATORY EQUIPMENT IF DEEMED NECESSARY.
Ventilation:NOT NORMALLY REQUIRED. LOCAL EXHAUST: IN ADDITION TO
GENERAL VENTILATION OPTIONAL.
Protective Gloves:OIL IMPERVIOUS TYPE SUCH AS NEOPRENE
Eye Protection:CHEMICAL SPLASH GOGGLES/SAFETY GLASSES
Other Protective Equipment:IMPERVIOUS GARMENTS
Work Hygienic Practices:DON'T WEAR CONTAMINATED CLOTHING. LAUNDER
BEFORE REUSE OR DISCARD.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:>600F
Spec Gravity:0.88
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER FLUID, PETROLEUM ODOR.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT, OPEN FLAME, & OTHER SOURCES OF
IGNITION
Hazardous Decomposition Products:SMOKE, FUMES, CO, CO2, MINOR AMOUNTS
OF VARIOUS HYDROCARBONS, OXIDES OF SULFUR
Disposal
Waste Disposal Methods:ALL RECOVERED MATERIAL SHOULD BE
PACKAGED/LABELLED/TRANSPORTED/DISPOSED OF/RECLAIMED IN CONFORMANCE
W/GOOD ENGINEERING PRACTICES. DISPOSE ACCORDING TO
LOCAL/STATE/FEDERAL REGULATIONS REGARDING HEALTH/ AIR/WATER
POLLUTION. DISPOSE OF USED OIL PROPERLY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.